Lenord + Bauer

SeGMo-Assist GELSEPOD

SeGMo-Assist GELSEPOD

SeGMo-System

GEL SEPOD

Position display for rotary and linear position measurements

Highlights

  • Plastic housing, ABS
  • Operating temperature range 0 °C to +60 °C [32 °F to 140 °F]
  • Bright graphical display – Representation of customized pictograms
  • Degree of protection IP65
  • Communication interfaces1): CAN bus with CANopen protocol (profile CiA 406) or IO-Link
  • cULus Component Recognition
Show all highlights (14)
  • Batteryless magnetic absolute multiturn encoder
  • Through hollow shaft 20H7 mm [0,79H7 in], stainless steel
  • Not sensitive to EMC interference
  • Simple cabling
  • Extremely compact for confined installation situations
  • Ready for use directly after switching on the power supply due to absolute position detection of the magnetic-absolute multiturn encoder
  • Freely programmable pictograms for easy user navigation
  • Maintenance-free electrical parts

Key parameters

Degree of protection
IP65
Interface
CANopen · IO-Link
Supply voltage
20–30 V DC

Technical data

Show all parameters (41)

The data describe technical versions, not order numbers. We will help you choose a specific version.

Versions: GEL SEPODR · GEL SEPODL. Shared values are listed once, differing ones for each version.

Electrical data

Supply voltage UB (polarity reversal protection, overvoltage protection)
20 to 30 V DC
Current consumption
  • GEL SEPODR: ≈30 mA at 24 V DC
  • GEL SEPODL: Without external sensor: approximately 30 mA at 24 V DC; Maximum current consumption with connected external sensor: 80 mA
Power consumption
Power supply unit requirements: Maximum supply output: 100 VA
Communication interfaces
CAN bus with CANopen protocol (CiA 406 profile); IO-Link; no electrical isolation

Mechanical data

Sensor shaft
  • GEL SEPODR: Through hollow shaft; ■ Diameter: 20 mm H7 [0.79H7]; ■ Material: stainless steel; Shaft sealing ring; ■ Material: FKM
  • GEL SEPODL: —
Maximum permissible rotational speed
  • GEL SEPODR: 100 min⁻¹ at DuCy = 25 % (DuCy = duty cycle)
  • GEL SEPODL: —
Housing material
Plastic ABS, anthracite
Viewing window material
Plastic, impact-resistant
Housing dimensions (excluding connection elements, excluding torque support)
  • GEL SEPODR: 48 mm × 56 mm × 70 mm [1.89 in × 2.20 in × 2.76 in]
  • GEL SEPODL: —
Weight
  • GEL SEPODR: ≈170 g [6.0 oz]
  • GEL SEPODL: ≈100 g [3.53 oz]
Housing dimensions (excluding connection elements)
  • GEL SEPODR: —
  • GEL SEPODL: 48 mm × 50 mm × 70 mm [1.89 in × 1.97 in × 2.76 in]

Encoder data

Scanning
  • GEL SEPODR: Magnetic, absolute
Resolution
  • GEL SEPODR: 1000 increments per 360° (freely configurable)
Measuring system detection range
  • GEL SEPODR: ■ In energized state: unlimited; ■ In de-energized state: 129 revolutions

Connection elements

Communication interface and supply voltage
5-pin male M12 connector, A-coded
Functional ground connection
6.3 mm [0.25 in] flat connector
Sensor connection
  • GEL SEPODR: —
  • GEL SEPODL: 8-pin female connector M12, A-coded

Controls

Push-button
3 membrane push buttons

Indicators

Display
OLED 1.54” monochrome, yellow (128 × 64 pixels, graphic), Language: English

Ambient data

Operating temperature range
0 °C to +60 °C [32 °F to 140 °F]
Storage temperature range
-20 °C to +80 °C [-4 °F to 176 °F]
Maximum relative air humidity
Condensation not permitted
Degree of protection
IP65; as per DIN EN 60529:2014-09; (Degree of protection not rated by UL!)
Dielectric strength
500 V AC; as per DIN EN 61439-1:2012-06
EMC
DIN EN 61326-1:2013-07; Class B device with immunity requirements for industrial environments

Only use screened connection cables for CAN-Bus (CO) communication interface.

Vibration resistance
1 to 100 m/s² [3.28 to 328.08 ft/s²], 5 to 15 Hz; 100 m/s² [328.08 ft/s²], 15 to 159 Hz; as per DIN EN 60068-2-6:2008-10
Shock resistance
800 m/s² [2624.67 ft/s²], 6 ms; as per DIN EN 60068-2-27:2010-02

Data for "cULus Recognized Component"

Housing type
Closed
Device function
Process control device
Connection to main power supply
No
Overvoltage category
II
Contamination level
2
Guards
Class III; (Class SELV or PELV and limited power or LPS)
Atmospheric humidity
Maximum 80 % at temperatures up to 31 °C [87.8 °F], linearly decreasing to 50 % relative humidity at 40 °C [104 °F]
Installation altitude
≤ 2000 m [1.24 mi]
Use in wet areas
No
Device mobility
Fixed
Operating conditions
Continuous
Classification according to UL61010-1 standards
Type 1

Approvals

European Economic Area
Conformity in accordance with EMC Directive 2014/30/EU
USA and Canada
  • GEL SEPODR: Certification as cULus Recognized Component
  • GEL SEPODL: Certification as cULus Recognized Component

    The UL certification also applies to the combination of position display and connected GEL SELIN linear sensor, even though the linear sensor does not have its own UL certification.

Source of the technical data

Documents 6

Interested in more products?

Build an inquiry from several items.

Add products to the inquiry cart and send our team a single combined inquiry.

Back to the catalogue

Do you have a technical question?

Need to check compatibility, request 3D models or technical documentation? Write to us and our team of engineers will get back to you promptly.

* Required field

From choosing components to a complete technical system