Lenord + Bauer

SeGMo-Positioning GEL6008

SeGMo-Positioning GEL6008

SeGMo-System

GEL 6008

Compact positioning drive for confined installation situations with through hollow shaft

Highlights

  • Nominal torque 2 Nm [1.48 ft•lbf]
  • Aluminum housing
  • Operating temperature range -10 °C to +50 °C [14 °F to 122 °F]
  • Stepping motor
  • Batteryless magnetic-absolute multiturn encoder
  • Degree of protection IP65
Show all highlights (14)
  • Integrated communication interface IO-Link
  • Optional with display (In preparation)
  • cULus Component Recognition(In preparation)
  • Extremely compact for confined installation situations
  • Monitoring equipment to aid trouble-free operation
  • Ready for use directly after switching on the power supply due to absolute position detection of the magnetic-absolute multiturn encoder
  • Maintenance-free electrical parts
  • Maintenance-free gear due to sealed-for-life lubrication

Key parameters

Degree of protection
IP65
Interface
IO-Link
Supply voltage
24–30 V DC

Technical data

Show all parameters (36)

The data describe technical versions, not order numbers. We will help you choose a specific version.

Versions: GEL 6008 – 02 / 0 (K) Without display · GEL 6008 – 02 / 2 (K) With display. Shared values are listed once, differing ones for each version.

Controls

Buttons
  • GEL 6008 – 02 / 0 (K) Without display: -
  • GEL 6008 – 02 / 2 (K) With display: 3 membrane buttons

Approvals

USA and Canada
Design C:; Certification as cULus Recognized Component
European Economic Area
Conformity in accordance with EMC Directive 2014/30/EU Machinery Directive 2006/42/EC

Ambient data

EMC
Electromagnetic immunity; DIN EN 61000-6-1:2007-10, EN 61000-6-1:2007; DIN EN 61000-6-2:2006-03 + correction1:2011-06,; EN 61000-6-2:2005 + AC:2005; IO-Link:; DIN EN 61000-4-5:2019-03 (±1 kV Line-Earth/±0,5 kV Line-Line); Electromagnetic emission; DIN EN 61000-6-3:2011-09 + correction1:2012-11,; EN 61000-6-3:2007 + A1:2011 + AC:2012,; DIN EN 61000-6-4:2011-09, EN 61000-6-4:2007 + A1:2011
Condensation
Not permitted
Noise emission
tbd
Shock resistance
150 m/s2 [492.13 ft/s2] (≈ 15g) @ 6 ms;; as per DIN EN 60068-2-27:2010-02
Dielectric strength
√ 2× 500 V DC; as per DIN EN 61439-1:2012-06
Degree of protection
IP65, DIN EN 60529:2014-09, shaft sealing ring (material: FKM)
Vibration resistance
50 m/s2 [164.04 ft/s2] (≈ 5g) @ 10 to 150 Hz;; as per DIN EN 60068-2-6:2008-10
Storage temperature range
-20 °C to +70 °C [-4 °F to +158 °F]
Working temperature range
0 °C to +50 °C [32 °F to 122 °F]
Operating temperature range
-10 °C to +50 °C [14 °F to 122 °F]
Maximum relative air humidity
90 %

Encoder data

Resolution
1,000 increments per 360°
Measuring system detection range
In energized state: unlimited; In de-energized state: 119 revolutions

Electrical data

Communication interfaces
IO-Link
Supply voltage, logic circuit
20 V to 30 V DC (Nominal supply voltage: 24 V DC)
Supply voltage, power circuit
24 V to 30 V DC; (Nominal supply voltage: 24 V DC); ( Maximum motor speed depends on voltage!)
Duty cycle DuCy in % (load-dependent)
DuCy = 25 % at 100 % load torque, duty type S2; “Base time 4 minutes: Duty cycle (DuCy) = 1 minute,; Break duration (BD)= 3 minutes”
Maximum current consumption, power circuit
1.8 A
Maximum current consumption, logic circuit
  • GEL 6008 – 02 / 0 (K) Without display: 10 mA
  • GEL 6008 – 02 / 2 (K) With display: 30 mA

Mechanical data

Output shaft
Through hollow shaft 20H7 mm [0.8 H7 in]
Housing material
Aluminum
Weight E/A in kg [lb]
≈1.0 kg [2.20 lb]
Nominal torque output shaft
2.0 Nm at 30 min-1 [1.48 ft • lbf at 30 r.p.m.]
Housing dimensions, Without connectors
  • GEL 6008 – 02 / 0 (K) Without display: 35 mm×95 mm×100 mm; [1.38 in×3.74 in×3.94 in]
  • GEL 6008 – 02 / 2 (K) With display: 35 mm×95 mm×104 mm; [1.38 in×3.74 in×4.09 in]

Display elements

Display
  • GEL 6008 – 02 / 0 (K) Without display: -
  • GEL 6008 – 02 / 2 (K) With display: TFT display

Connecting Elements

Functional ground connection
6.3 mm [0.25 in] flat plug
Communication interface and supply voltage
Pin connector, M12 A-coded

Data for "cULus Recognized Component” (version C)

Enclosure type
Type 1
Working temperature range
In preparation
Operating temperature range
In preparation
Input voltage (power circuit) UIN
24 V to 30 V DC
cULus Recognized Component, E196161
In preparation
Input power (power circuit), Duty cycle (DuCy) = 1 minute, Break duration (BD) = 3 minutes
In preparation
Source of the technical data

Documents 3

Interested in more products?

Build an inquiry from several items.

Add products to the inquiry cart and send our team a single combined inquiry.

Back to the catalogue

Do you have a technical question?

Need to check compatibility, request 3D models or technical documentation? Write to us and our team of engineers will get back to you promptly.

* Required field

From choosing components to a complete technical system