Lenord + Bauer

SeGMo-Positioning GEL6109

SeGMo-Positioning GEL6109

SeGMo-System

GEL 6109

Compact positioning drive for confined installation situations

Highlights

  • Nominal torques 2.5 Nm [1.84 ft•lbf], 5 Nm [3.69 ft•lbf]
  • Aluminum housing, anodized
  • Operating temperature range -10 °C to +60 °C [14 °F to 140 °F]
  • Brushless DC motor
  • Batteryless magnetic absolute multiturn encoder
  • Degree of protection IP67
Show all highlights (14)
  • Integrated communication interfaces CANopen (CiA 402); EtherCAT; IO-Link; EtherNet/IP; Modbus/TCP; POWERLINK; PROFINET IO/RT; sercos III
  • Optional with cULus Component Recognition
  • Extremely compact for confined installation situations
  • Either hybrid cable or connector outlet
  • Monitoring equipment to aid trouble-free operation
  • Ready for use directly after switching on the power supply due to absolute position detection of the magnetic-absolute multiturn encoder
  • Maintenance-free electrical parts
  • Maintenance-free gear due to sealed-for-life lubrication

Key parameters

Degree of protection
IP67
Interface
CANopen · EtherCAT · EtherNet/IP · IO-Link · Modbus/TCP · POWERLINK · PROFIBUS · PROFINET · sercos III
Supply voltage
24–30 V DC

Technical data

Show all parameters (33)

The data describe technical versions, not order numbers. We will help you choose a specific version.

Versions: GEL 6109 – 02 (K) · GEL 6109 – 05 (L). Shared values are listed once, differing ones for each version.

Approvals

USA and Canada
Design C:; Certification as cULus Recognized Component
European Economic Area
Conformity in accordance with EMC Directive 2014/30/EU Machinery Directive 2006/42/EC

Ambient data

EMC
Electromagnetic immunity; DIN EN 61000-6-1:2007-10, EN 61000-6-1:2007; DIN EN 61000-6-2:2006-03 + correction1:2011-06,; EN 61000-6-2:2005 + AC:2005; IO-Link:; DIN EN 61000-4-5:2019-03 (±1 kV Line-Earth/±0,5 kV Line-Line); Electromagnetic emission; DIN EN 61000-6-3:2011-09 + correction1:2012-11,; EN 61000-6-3:2007 + A1:2011 + AC:2012,; DIN EN 61000-6-4:2011-09, EN 61000-6-4:2007 + A1:2011
Condensation
Not permitted (condensation protection upon request)
Noise emission
Maximum 50 dB(A)
Shock resistance
150 m/s2 [492.13 ft/s2] (≈ 15g) @ 6 ms;; as per DIN EN 60068-2-27:2010-02
Dielectric strength
√ 2× 500 V DC; as per DIN EN 61439-1:2012-06
Degree of protection
IP67, DIN EN 60529:2014-09, shaft sealing ring (material: FKM)
Vibration resistance
50 m/s2 [164.04 ft/s2] (≈ 5g) from 10 to 50 Hz Hz; according to DIN EN 60068-2-6 standard: 2008-10
Working temperature range
0 °C to +60 °C [32 °F to 140 °F]
Operating temperature range
-10 °C to +60 °C [14 °F to 140 °F]
Maximum relative humidity
95 %
Storage temperature range
-20 °C to +85 °C [-4 °F to +185 °F]

Encoder data

Resolution
1,000 increments per 360°
Measuring system detection range
In energized state: unlimited; In de-energized state: 342 revolutions

Electrical data

Communication interfaces
CANopen (CiA 402); PROFIBUS-DP (V0/V1); EtherCAT; IO-Link; EtherNet/IP; Modbus/TCP; POWERLINK; PROFINET IO/RT; sercos III
Supply voltage, logic circuit
24 V to 30 V DC (Nominal supply voltage: 24 V DC)
Supply voltage, power circuit
24 V to 30 V DC; (Nominal supply voltage: 24 V DC); ( Maximum motor speed depends on voltage!)
Duty cycle DuCy in % (load-dependent)
DuCy = 25 % at 100 % load torque, duty type S2 “Base time 4 minutes: Duty cycle (DuCy) = 1 minute, Break duration (BD) = 3 minutes DuCy ≤ 50 % at reduced load torque, depending on environmental parameters and application
Power circuit current consumption (Maximum power circuit current consumption)
  • GEL 6109 – 02 (K): 1.8 A (4.0 A)
  • GEL 6109 – 05 (L): 2.6 A (5 A)
Maximum current consumption, logic circuit connection technology: - H1/H2/H3/HS/S1/S2/S3/SL/xx/Vx - ST
- 100 mA; - 200 mA

Mechanical data

Weight
  • GEL 6109 – 02 (K): ≈1.0 kg [2.21 lb]
  • GEL 6109 – 05 (L): ≈1.25 kg [2.76 lb]
Output shaft
Semi-hollow shaft, solid shaft, customized shaft
Housing material
Aluminum, anodized
Housing dimensions
50 mm [1.97 in]×125 mm [4.92 in]×L
Nominal torque output shaft
  • GEL 6109 – 02 (K): 2.5 Nm at 70 min-1; [1.84 ft•lbf at 70 r.p.m.]
  • GEL 6109 – 05 (L): 5 Nm at 70 min-1; [3.69 ft•lbf at 70 r.p.m.]

Data for "cULus Recognized Component” (version C)

Enclosure type
Type 1
Working temperature range
0 °C to +55 °C [32 °F to 131 °F]
Operating temperature range
-10 °C to +55 °C [14 °F to 131 °F]
Input voltage (power circuit) UIN
24 V to 30 V DC
cULus Recognized Component, E196161
UL 61800-5-1 CSA C22.2 number 274-13
Input power (power circuit), Continuous operation
  • GEL 6109 – 02 (K): 25 VA [0.03 hp]
  • GEL 6109 – 05 (L): 45 VA [0.06 hp]
Input power (power circuit), Duty cycle (DuCy) = 1 minute, Break duration (BD) = 3 minutes
  • GEL 6109 – 02 (K): 35 VA [0.05 hp]
  • GEL 6109 – 05 (L): 60 VA [0.08 hp]
Source of the technical data

Documents 6

Interested in more products?

Build an inquiry from several items.

Add products to the inquiry cart and send our team a single combined inquiry.

Back to the catalogue

Do you have a technical question?

Need to check compatibility, request 3D models or technical documentation? Write to us and our team of engineers will get back to you promptly.

* Required field

From choosing components to a complete technical system