Highlights

  • Resolution of rotary encoder: 80 pulses per revolution (others upon request)
  • Degree of protection (overall system): IP66, IP67
  • Housing material: Aluminum, coated
  • Cold movement detection monitors wheel axle movements in de-energized state
  • Energy self-sufficient, no battery required
  • Maintenance-free, durable operation in extremely harsh ambient conditions due to the magnetic measuring system

Key parameters

Output signal
Square-wave signal
Degree of protection
IP66 · IP67
Frequency range (max.)
0–25 kHz
Supply voltage
10–30 V DC

Technical data

Show all parameters (42)

The data describe technical versions, not order numbers. We will help you choose a specific version.

Versions: GEL 2740 – 2740V0 · GEL 2740 – 2740V1 · GEL 2740 – 2740V2 · GEL 2740 – 2740V3 · GEL 2740 – Incremental encoder · GEL 2740 – Cold Movement Detection · GEL 2740 – Incremental encoder – Electrical data – Frequency range – occurrence 1 · GEL 2740 – Incremental encoder – Electrical data – Frequency range – occurrence 2. Shared values are listed once, differing ones for each version.

General data

Output
  • 2740V0: -
  • 2740V1: Voltage
  • 2740V2: Voltage
  • 2740V3: Voltage
  • Cold Movement Detection: —
Phase offset
  • 2740V0: -
  • 2740V1: 90°
  • 2740V2: 90°
  • 2740V3: 90°
  • Cold Movement Detection: —
Measuring systems
  • 2740V0: CMD
  • 2740V1: CMD + incremental encoder up to 3 × 2 channels possible
  • 2740V2: CMD + incremental encoder up to 3 × 2 channels possible
  • 2740V3: CMD + incremental encoder up to 3 × 2 channels possible
  • Cold Movement Detection: —
Incremental encoder
  • 2740V0: -
  • 2740V1: 2 channels
  • 2740V2: 2 x 2 channels
  • 2740V3: 3 x 2 channels
  • Cold Movement Detection: —
Resolution (number of pulses)
  • 2740V0: -
  • 2740V1: 80 pulses per revolution
  • 2740V2: 80 pulses per revolution
  • 2740V3: 80 pulses per revolution
  • Cold Movement Detection: —
Inputs
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Cold Movement Detection: UB_Mag; UB_Load
Outputs
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Cold Movement Detection: Out1; Out2; Out3; Out4

Mechanical data

Shaft material
  • 2740V0: Stainless steel
  • 2740V1: Stainless steel
  • 2740V2: Stainless steel
  • 2740V3: Stainless steel
  • Incremental encoder: —
  • Cold Movement Detection: —
Housing material
  • 2740V0: Aluminum, coated
  • 2740V1: Aluminum, coated
  • 2740V2: Aluminum, coated
  • 2740V3: Aluminum, coated
  • Incremental encoder: —
  • Cold Movement Detection: —
Degree of protection
  • 2740V0: IP66, IP67
  • 2740V1: IP66, IP67
  • 2740V2: IP66, IP67
  • 2740V3: IP66, IP67
  • Incremental encoder: —
  • Cold Movement Detection: —
Maximum permissible rotational speed
  • 2740V0: 5000 r.p.m.-1
  • 2740V1: 5000 r.p.m.-1
  • 2740V2: 5000 r.p.m.-1
  • 2740V3: 5000 r.p.m.-1
  • Incremental encoder: —
  • Cold Movement Detection: —
Weight (excluding cable, excluding drive)
  • 2740V0: 2000 g
  • 2740V1: 3667 g
  • 2740V2: 3667 g
  • 2740V3: 3667 g
  • Incremental encoder: —
  • Cold Movement Detection: —
Cable data
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Incremental encoder: halogen-free, screened
  • Cold Movement Detection: halogen-free, screened
Cable diameter
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Incremental encoder: 8.0 ± 0.3 mm
  • Cold Movement Detection: 10.5 ± 0.4 mm
Cable cross section
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Incremental encoder: 12 × 0.34 mm2
  • Cold Movement Detection: 8 × 0.5 mm2
Minimum bending radius static
  • 2740V0: —
  • 2740V1: —
  • 2740V2: —
  • 2740V3: —
  • Incremental encoder: 120 mm
  • Cold Movement Detection: 120 mm

Environmental tests

Type test
  • 2740V0: DIN EN 50155:2022-06
  • 2740V1: DIN EN 50155:2022-06
  • 2740V2: DIN EN 50155:2022-06
  • 2740V3: DIN EN 50155:2022-06
Fire protection
  • 2740V0: Hazard level HL2 (R22)/HL3 (R23); as per DIN EN 45545-2:2020-10
  • 2740V1: Hazard level HL2 (R22)/HL3 (R23); as per DIN EN 45545-2:2020-10
  • 2740V2: Hazard level HL2 (R22)/HL3 (R23); as per DIN EN 45545-2:2020-10
  • 2740V3: Hazard level HL2 (R22)/HL3 (R23); as per DIN EN 45545-2:2020-10
Shock resistance
  • 2740V0: DIN EN 61373:2011-04 cat. 3
  • 2740V1: DIN EN 61373:2011-04 cat. 3
  • 2740V2: DIN EN 61373:2011-04 cat. 3
  • 2740V3: DIN EN 61373:2011-04 cat. 3
Dielectric strength
  • 2740V0: 500 V AC / 750 V DC (DIN EN 50155:2022-06)
  • 2740V1: 500 V AC / 750 V DC (DIN EN 50155:2022-06)
  • 2740V2: 500 V AC / 750 V DC (DIN EN 50155:2022-06)
  • 2740V3: 500 V AC / 750 V DC (DIN EN 50155:2022-06)
Storage temperature
  • 2740V0: -40 °C to +105 °C
  • 2740V1: -40 °C to +105 °C
  • 2740V2: -40 °C to +105 °C
  • 2740V3: -40 °C to +105 °C
Vibration resistance
  • 2740V0: DIN EN 61373:2011-04 cat. 3
  • 2740V1: DIN EN 61373:2011-04 cat. 3
  • 2740V2: DIN EN 61373:2011-04 cat. 3
  • 2740V3: DIN EN 61373:2011-04 cat. 3
Max. relative air humidity
  • 2740V0: 98 %, condensation possible
  • 2740V1: 98 %, condensation possible
  • 2740V2: 98 %, condensation possible
  • 2740V3: 98 %, condensation possible
Electromagnetic compatibility
  • 2740V0: DIN EN 50121-3-2:2017-11
  • 2740V1: DIN EN 50121-3-2:2017-11
  • 2740V2: DIN EN 50121-3-2:2017-11
  • 2740V3: DIN EN 50121-3-2:2017-11
Working and operating temperature
  • 2740V0: -40 °C to +100 °C
  • 2740V1: -40 °C to +100 °C
  • 2740V2: -40 °C to +100 °C
  • 2740V3: -40 °C to +100 °C
Maximum installation altitude above sea level
  • 2740V0: ≤ 2000 m, as per DIN EN 61010-1:2020-03
  • 2740V1: ≤ 2000 m, as per DIN EN 61010-1:2020-03
  • 2740V2: ≤ 2000 m, as per DIN EN 61010-1:2020-03
  • 2740V3: ≤ 2000 m, as per DIN EN 61010-1:2020-03

Electrical data

Duty cycle
  • Incremental encoder: 50 % ± 20 %
  • Cold Movement Detection: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Screen connection
  • Incremental encoder: capacitive
  • Cold Movement Detection: capacitive
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Output signal level Low
  • Incremental encoder: ≤ 2.0 V
  • Cold Movement Detection: ≤ 2.0 V
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Output signal level High
  • Incremental encoder: ≥ UB - 2.0 V
  • Cold Movement Detection: ≥ UB - 2.0 V
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Supply voltage UB (reverse polarity protected)
  • Incremental encoder: 10 to 30 V DC
  • Cold Movement Detection: 10 to 30 V DC
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Current consumption IB per channel (without load)
  • Incremental encoder: ≤ 30 mA
  • Cold Movement Detection: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Output signal (short-circuit-proof, push-pull power amplifier)
  • Incremental encoder: Square-wave signals
  • Cold Movement Detection: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Activation time Ta
  • Incremental encoder: —
  • Cold Movement Detection: ≥ 6 ms
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Max. current (in ULoad)
  • Incremental encoder: —
  • Cold Movement Detection: ≤ 180 mA
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Minimum charging time TL
  • Incremental encoder: —
  • Cold Movement Detection: 70 ms (at one charging voltage of 24 V)
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Current consumption (without load)
  • Incremental encoder: —
  • Cold Movement Detection: in reading mode < 35 mA
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: —
Frequency range
  • Incremental encoder: —
  • Cold Movement Detection: —
  • Incremental encoder – Electrical data – Frequency range – occurrence 1: 0 to 20 kHz
  • Incremental encoder – Electrical data – Frequency range – occurrence 2: 0 to 25 kHz

Cable protection

Type
  • Incremental encoder: Metal protective sleeve
  • Cold Movement Detection: Metal protective sleeve
Material
  • Incremental encoder: Steel galvanized;; sheath: thermoplastic polyurethane
  • Cold Movement Detection: Steel galvanized;; sheath: thermoplastic polyurethane
Outside diameter
  • Incremental encoder: 21.1 mm
  • Cold Movement Detection: 21.1 mm
Minimum bending radius static
  • Incremental encoder: 120 mm
  • Cold Movement Detection: 120 mm
Source of the technical data

Documents 2

Interested in more products?

Build an inquiry from several items.

Add products to the inquiry cart and send our team a single combined inquiry.

Back to the catalogue

Do you have a technical question?

Need to check compatibility, request 3D models or technical documentation? Write to us and our team of engineers will get back to you promptly.

* Required field

From choosing components to a complete technical system